Item | Specifications | ||||||||
Model | DA2YZ _ _ | DA2Z1_ _ | DA212_ _ | DA224 _ _ | DA238 _ _ | DA24A _ _ | DA26B _ _ | DA28C _ _ | |
Compatible Motor | M□500 | M□101 | M□201 | M□401 | M□751 | M□102 | M□152 | MM202 | |
External dimensions | See "Dimensions" beginning on page 31. | ||||||||
Weight (kg) | 0.7 | 0.8 | 1.0 | 1.6 | |||||
Input power
|
Main circuit power | Single-phase AC200 V to 240 V ± 10 % 50 / 60 Hz |
Three-phase AC200 V to 240 V (*1) ± 10 % 50 / 60 Hz |
||||||
Control power (*2) | DC24V ±10 % | ||||||||
Input current (Arms typ)
|
0.8
|
1.3
|
2.4
|
3.6
|
7.2
|
Single-phase : 9.7 |
6.6
|
9.0
|
|
Three-phase : 5.1 | |||||||||
Control power Current Consumption (mA Typ.)
|
170 | 210 | 260 | 350 | |||||
Inrush current approx.1.4 A | |||||||||
Control type Three-phase PWM inverter sine-wave driven | |||||||||
Output Rating
|
Rated current(A ) 0.7 | 1.0 | 1.7 | 2.7 | 4.3 | 5.6 | 9.9 | 12.2 | |
Output frequencies(Hz ) 0 to 500 | 0 to 250 | ||||||||
Encoder feedback 17 bit single-turn absolute (The product can function as a multi-turn absolute type when batteries are added.) |
|||||||||
Control signal
|
Input | 8-point (24 VDC system, opto-coupler input insulation) inputs whose functions are switched by the control mode | |||||||
Output | 8-point (24 VDC system, open-collector output insulation) outputs whose functions are switched by the control mode | ||||||||
Analog signal | Input | Single ended (±10 V) input whose functions can be switched by the control mode | |||||||
Pulse signal
|
Input
|
RS-422 differential | |||||||
Open-collector | |||||||||
Output
|
Encoder feedback pulse (A-/B-/Z-phase), RS-422 differential output | ||||||||
Z-phase pulse through open-collector as wel | |||||||||
Communication function
|
USB : connection to PC with“Digitax SF Connect”installed | ||||||||
RS-485 : host remote control communication (multi-drop compatible) | |||||||||
Drive status display function
|
Drive status display function 6 digits of seven-segment display on Setup Panel | ||||||||
Normal/Error display on STATUS LED | |||||||||
Green light when Power ON Normal, Red light when Power ON Error, Dim when Power OFF | |||||||||
Regeneration function | A braking resistor may be installed externally (*3) | ||||||||
Control mode | Position Control, Velocity Control, Torque Control |