MBA01A01 Dây cáp nguồn Control Techniques 50-750W Fixed 1m

SKU
MBA01A01
Còn hàng
1.000 ₫
-
+
Tổng Quan

Thông số kỹ thuật cable MBA01A01

- Low-smoke, halogen-free and flame-retardant construction (PUR jacket type).

- Power cables and connectors UL recognised.

- Complies with DESINA coding - Orange for power,

- Green for signal.

- Optimum noise immunity.

- No need for crimp and insertion / removal tools.

- Encoder cable has low voltage drop for longer cable lengths and separately screened thermistor wires.

- Pre-assembled cables offer consistent quality at competitive prices.

- Power cables either with or without brake wires.

- Cable assembly type identification label.

- Brake wires are separately shielded within the power

- Cable.

Chi tiết Cable MBA01A01

Cables form an integral part of a servo system installation.
The ready made cables from Control Techniques allow system
installers to avoid intricate, time consuming assembly normally
associated with connecting servo systems.

Cable Order

Cable Order

POWER CABLE

Phase and conductor size (current rating CEI EN 60204-1:2006-09 at
40° C - installation method B2)
Power + number of cores x cross section (mm²) Nominal outer diameter (mm) MS Nominal outer diameter (mm) MB Tolerance (mm)
1 mm² ( 10.1 Amps ) 4G1 + ( 2 x 0.5 )
8.1
9.9
± 0.3
MQ = 1 mm² ( 10.1 Amps ) 4G1 + 2 x ( 2 x 0.5 )
2.5 mm² ( 17.4 Amps ) 4G2.5 + ( 2 x 0.5 ) 10.9 12.5 ± 0.3
4 mm² ( 23 Amps ) 4G4 + ( 2 x 1 ) 12.1 12.5 ± 0.3
6 mm² ( 30 Amps ) 4G6 + ( 2 x 1 ) 14.8 16.2 ± 0.4
10 mm² ( 40 Amps ) 4G10 + ( 2 x 1 ) 18.3 19.5 ± 0.4
16mm² ( 54 Amps ) 4G16 + ( 2 x 1 ) 21.4 21.6 ± 0.5
25 mm² ( 70 Amps ) 4G25 + ( 2 x 1 ) 26.5 26.9 ± 0.5

SIGNAL CABLE

Cable code and type Construction cross section (mm²) Nominal outer diameter (mm) Tolerance (mm)
SI - ( Incremental encoder + SinCos EnDat 2.1 ) 6 x 2 x 0.25 + 1 x 2 x 0.34 + 1 x 2 x 0.50 mm² 10.2 ± 0.3
SR - ( Resolver ) 4 x ( 2 x 0.25 ) ST mm² 8.9 ± 0.3
SS - ( Sincos Hiperface Encoder ) 4 x ( 2 x 0.15 ) + 1 x 2 x 0.50 mm² 7.3 ± 0.3
SE - ( Serial EnDat 2.2 only ) 4 x ( 2 x 0.15 ) + 1 x 2 x 0.50 ST mm² 7.3 ± 0.3

HYBRID CABLE (POWER AND SIGNAL COMBINED)

Phase and conductor size (current rating CEI EN 60204-1:2006-09 at
40° C - installation method B2)
Construction cross section (mm²) Nominal outer diameter (mm) Tolerance (mm)
A - 1.5 mm² + 0.75 mm² ( 13.1 Amps ) 4G1.5 + ( 2 x 0.75 ) ST+ ( 2 x AWG24 ) + 2x ( 2 x AWG28 ) 13.7 ± 0.3
B - 2.5 mm² + 1 mm² ( 17.4 Amps ) 4G2.5 + ( 2 x 0.75 ) ST+ ( 2 x AWG24 ) + 2x ( 2 x AWG28 ) 14.8 ± 0.3
C - 4 mm² + 1 mm² ( 23 Amps ) 4G4.0 + ( 2 x 1.0 ) ST+ ( 2 x AWG24 ) + 2x ( 2 x AWG28 ) / ST 16.1 ± 0.3

Cable Control Technique Manual

Thông số sản phẩm
Dòng điện định mức N/A
Điện áp cuộn coil N/A
Xuất xứ N/A
Thời gian bảo hành N/A