Driver Nidec Commander S100-01113-0A0000
Marshal | |
Offline Programming | Program the drive while it is still in the box |
Cloning | Clone parameter sets from one drive to another |
Faststart | Guided commissioning and motor rotation verification test |
Guided Diagnostics | Easy fault finding |
Parameter File Storage | Save parameter files to the device or cloud for future use |
Share Project Configuration | Share to colleagues or to Control Techniques Technical Support for diagnostics |
Pdf Parameter Set | Useful for sharing parameter sets for quick review |
Wiring Diagram | Automatically generate a printable pdf of a custom wiring diagram for your installation |
Non-Default Parameter | Show the parameters that have been changed from their default setting |
Favourite Parameters | Favourite parameters visited often |
Guides And Manuals | Quick access to drive documentation |
Modbus RTU Communications | Logic function control |
Control Word Control | √ |
Cloning | √ |
Serial Baud Rate | 600 to 115000 bps |
Modbus Rtu Protocol | 8.2NP, 8.1NP, 8.1EP, 8.1OP |
Reference | |
Selectable References | 4 |
Jog Reference | √ |
Up / Down % Reference (Motorised Pot) | √ |
Bi-Polar Reference | √ |
Preset Speeds | 4 |
Skip Frequencies | 1 |
Skip Frequencies Dead Band | √ |
Local/Remote | √ |
S-Ramp | √ |
Acceleration Rates | 2 |
Deceleration Rates | 2 |
Frequency Input Reference (Pulse Train) | 0 Hz to 100 kHz |
Run Reverse | √ |
Application Specific | |
PID Controller | PI Control |
PID Feedforward | √ |
PID Threshold Detector | √ |
PID Slew Rate | √ |
Reference Configuration | √ |
Run/Stop Configuration | √ |
Input Scaling | 4-point |
Run Permit (Latching Run) | √ |
Limit Switches | √ |
Control | |
Control Mode: Linear V to F | √ (Definable Boost) |
Control Mode: Square V to F | √ (Definable Boost) |
Control Mode: Resistance Compensation | √ |
Low Energy Mode (Dynamic V to F) | √ |
Motor Stability Optimiser | √ |
Slip Compensation | √ |
Auto-Tune: Static | √ |
Switching Frequency | 4 or 12 kHz |
Catch An Already Spinning Motor | √ |
Stop Mode: Ramp | √ |
Stop Mode: Coast | √ |
Stop Mode: Distance Stop | √ when selected it stops in the same distance from any speed based on the programmed deceleration rate |
Dc Injection Braking | √ |
Supply Loss Detection | √ |
Programmable Output Current Limit | √ |
General | |
Diagnostics | √ |
Error History Log | 4 |
Parameters Saved On Error | 3 (Selectable) |
Auto-Reset After Trip | √ |
Power Loss Ride Through | √ |
Security | 4-digit PIN protection |
Cooling Fan | Fixed Speed (No fan on S100-01x13 or S100-01x23 drives) |