S100-03423 Biến tần Control Techniques 4kw

SKU
S100-03423-0A0000
Còn hàng
5.712.476 ₫
-
+
Tổng Quan

Thông số kỹ thuật S100-03423-0A0000

- Voltage: 100-120 V | 200 - 240 V | 380 - 480 V

- Wattage: 4kw

- Ingress protection: IP20

- Motor control: Open loop vector or V/Hz induction motor control

- Terminals:

  • 2 x Analog Input, 1 x Analog Output
  • 4 x Digital Input, 1 Digital I/O
  • Single pole, double throw relay

- Communications: Modbus RTU on board

Thư mục: Biến tần  

Driver Nidec Commander S100-03423-0A0000

Marshal
Offline Programming Program the drive while it is still in the box
Cloning Clone parameter sets from one drive to another
Faststart Guided commissioning and motor rotation verification test
Guided Diagnostics Easy fault finding
Parameter File Storage Save parameter files to the device or cloud for future use
Share Project Configuration Share to colleagues or to Control Techniques Technical Support for diagnostics
Pdf Parameter Set Useful for sharing parameter sets for quick review
Wiring Diagram Automatically generate a printable pdf of a custom wiring diagram for your installation
Non-Default Parameter Show the parameters that have been changed from their default setting
Favourite Parameters Favourite parameters visited often
Guides And Manuals Quick access to drive documentation
Modbus RTU Communications Logic function control
Control Word Control
Cloning
Serial Baud Rate 600 to 115000 bps
Modbus Rtu Protocol 8.2NP, 8.1NP, 8.1EP, 8.1OP
Reference
Selectable References 4
Jog Reference
Up / Down % Reference (Motorised Pot)
Bi-Polar Reference
Preset Speeds 4
Skip Frequencies 1
Skip Frequencies Dead Band
Local/Remote
S-Ramp
Acceleration Rates 2
Deceleration Rates 2
Frequency Input Reference (Pulse Train) 0 Hz to 100 kHz
Run Reverse
Application Specific
PID Controller PI Control
PID Feedforward
PID Threshold Detector
PID Slew Rate
Reference Configuration
Run/Stop Configuration
Input Scaling 4-point
Run Permit (Latching Run)
Limit Switches
Control
Control Mode: Linear V to F √ (Definable Boost)
Control Mode: Square V to F √ (Definable Boost)
Control Mode: Resistance Compensation
Low Energy Mode (Dynamic V to F)
Motor Stability Optimiser
Slip Compensation
Auto-Tune: Static
Switching Frequency 4 or 12 kHz
Catch An Already Spinning Motor
Stop Mode: Ramp
Stop Mode: Coast
Stop Mode: Distance Stop √ when selected it stops in the same distance from any speed based on the programmed deceleration rate
Dc Injection Braking
Supply Loss Detection
Programmable Output Current Limit
General
Diagnostics
Error History Log 4
Parameters Saved On Error 3 (Selectable)
Auto-Reset After Trip
Power Loss Ride Through
Security 4-digit PIN protection
Cooling Fan Fixed Speed (No fan on S100-01x13 or S100-01x23 drives)

Biến tần Control Techniques  S100

Biến tần Control Techniques S100

Ảnh chụp sản phẩm

s100-03423-0a0000-anh-chup-san-pham

Thông số sản phẩm
Ứng dụng N/A
Dòng series N/A
Điện áp N/A
Thời gian bảo hành N/A
Xuất xứ N/A