Supply Requirements

100 V drive: 100 V to 120 V ±10 %

200 V drive: 200 V to 240 V ±10 %

400 V drive: 380 V to 480 V ±10 %

Maximum supply imbalance: 2 negative phase sequence (equivalent to voltage imbalance between phases)

Power Range 0.18 to 4 kW / 0.25 to 5 hp
Supply Frequency Range 45 to 66 Hz
Output Frequency/Speed Range to 300 Hz
Switching Frequency kHz or 12 kHz
Heavy Duty Overload Capability 50 for 60 (from cold), 50 for 8 (from hot)
Operating Modes Linear to F, Square V to F, Resistance Compensation
Stopping Modes

Coast, Ramp, Ramp & DC Injection Braking, DC

Injection Braking with 0 Hz detect, Timed DC Injection Braking, Distance Stop

Communications RJ45 for Modbus RTU, NFC for app interface
Keypads

Fixed LED keypad,

Remote IP66 Keypad (available as an accessory)

User Software Tools

(Free To Download)

HMI (available as an accessory)

Marshal (Mobile App),

Connect (PC commissioning tool)

Analogue

2 x Analogue input

Possible settings: 0-10 V0-20 mA4-20 mA (No

Alarm), 4-20 mA (Alarm), 4-20 mA (Error),Digital

1 x Analogue output

Possible settings: 0-10 V, 0-20 mA, 4-20 mA

Digital

4 x Digital inputs (1 frequency input)

1 x Digital input / output (can be used as a frequency or PWM output to represent analog value)

Digital Input Logic Positive or Negative input logic (PNP or NPN sensors)
Relay x Relay (single pole, double throw relay)
Resolutions

Output frequency resolution: 0.1 Hz

Analogue input 1: 11 bit

Analogue input 2: 11 bit

Current: The resolution of the current feedback is 10

bit plus sign

IP Rating IP20
Storage Temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating Temperature Without De-Rate -10 °C to 40 °C (14 °Fto 104 °F)
Operating Temperature With De-Rate -10 °C to 60 °C (14 °F to 140 °F)
Cooling

Natural convection (frame 1 <0.25 kW / 0.33 hp), Integral cooling fan (all other drives)

Altitude <3000 (1000 m to 3000 derate % over 100 m)
Humidity 95 non-condensing at 40 °C /104 °F EN61800-2(3k3)
Pollution

Pollution degree dry, non-conducting pollution only

Commander S Highlights

Easy to install

The sleek curved design of Commander optimises component layout for small footprint and easy access to terminals. The click-on/click-off DIN rail mount makes installation remarkably easy.

Easy to use

Using our new Marshal app (Android/iOSyour drive can be configured in under 60 seconds.

Reliable

Durability is at the core of Commander designguaranteeing performance throughout its whole lifetime.

Cost effective

Equipped with unique features designed to save you timeenergy and money.

S100 Inverter Thông số kỹ thuật

S100-inverter-funtion

S100-inverter-funtion-2