Type
|
SV004 iC5-1
|
SV008 iC5-1
|
SV015 iC5-1
|
SV022 iC5-1
|
220V Class
|
Motor Rating
|
[HP]
|
0.5
|
1
|
2
|
3
|
[kW]
|
0.4
|
0.75
|
1.5
|
2.2
|
Output ratings
|
Capacity[kVA]
|
0.95
|
0.95
|
3.0
|
4.5
|
FLA[A]
|
2.5
|
0.95
|
3.0
|
4.5
|
Output frequency
|
0 ~ 400Hz
|
Output voltage
|
3 Phase 200 ~ 230V
|
Input ratings
|
Voltage
|
Single phase 200 ~ 230 V (±10%)
|
FLA[A]
|
5.5
|
9.2
|
16
|
21.6
|
Frequency
|
50 ~ 60 HZ (±5%)
|
Control
|
Control method
|
V/F control, Sersorless vector control
|
Frequency setting resolution
|
Digital reference: 0.01Hz
Analog reference: 0.6Hz/60Hz
|
Frequency setting resolution
|
Digital reference: 0.01Hz
Analog reference: 0.6Hz/60Hz
|
V/F ratio
|
Linear, Square pattern, User V/F
|
Overload capacity
|
1 min at 150%, 30 sec at 200% (with inverse characteristic)
|
Torque boost
|
Manual torque boost (0~15 adjustable), auto torque boost
|
Input signal
|
Operation method
|
Keypad/ Terminal/ Communications
|
Frequency setting
|
Analog: 0~10V / 4~20mA, Digital: Keypad,
Communication: RS485 (Option)
|
Start signal
|
Forward, Reverse
|
Multi-step accel/decal time
|
0.1~600 sec. Max. 8 types available by multi-function terminal, Selectable accel/decel patterns : Linear, U and S
|
Emergency stop
|
Interrupting the output of the drive
|
Jog
|
Jog operation
|
Fault reset
|
Reset the fault when protective function is active
|
Output signal
|
Operation status & fault output
|
Frequency detection, Overload alarm, Stalling, Overvoltage, Undervoltage, Drive overheating, Run, Stop, Constant speed, Speed searching, Fault output (Relay and Open collector output)
|
Indicator
|
Choose one from output frequency, current, voltage and DC voltage.(Output voltage: 0~10V)
|
Operation function
|
DC braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control
|
Protection functions
|
Drive trip
|
Overvoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload, External device fault 1.2, Loss of speed command, Hardware fault, Communication error, CPU error
|
Drive alarm
|
Stall prevention, Overload alarm
|
Momentary power loss
|
Less than 15 msec: keeping operation
More than 15 msec: auto restart available
|
Display Keypad
|
Operation information
|
Output frequency, current and voltage, Set frequency value, Operation speed, DC voltage
|
Trip information
|
Display the trip cause when the protection function activates. Recent 5 faults records stored
|
Environment
|
Anbient temperature
|
-10 ~ 40℃
|
Storage temperature
|
-20 ~ 65℃
|
Humidity
|
90 %RH max (No condensing)
|
Atmosphere
|
No corrosive gas, flammable gas, oil mist or dust
|
Pressure
|
70 ~ 106k Pa
|