GF4-T40N bộ đếm bộ định thời Hanyoung kỹ thuật số
Thông số kỹ thuật bộ đếm-Counter GF4-T40N
- In Timer function:
- Repeat accuracy: ±0.01 % ± 0.05 % second Max. (Power supply start)
- Variation due to voltage change: ± 0.005 % ± 0.003 % second Max. (Reset start)
- Variation due to temperature change: Ratio to set value
- Insulation resistance: 100 MΩ Min. (at 500 V d.c),(between current - carrying terminal and exposed noncurrent - carrying metal parts, between power supply circuit and control output circuit)
- Dielectric strength: 2,000 V a.c 50 / 60 Hz for 1 minute (between current - carrying terminal and exposed noncurrent - carrying metal parts, between power supply circuit and control output circuit)
- Noise immunity: Square wave noise by simulator, AC : ± 2 kV (between power supply terminal board), ± 500 V (between input terminal)
- Vibration: Mechanical durability : 10 to 55 Hz : 0.75 mm double amplitude, Malfunction durability : 10 to 55 Hz : 0.5 mm double amplitude
- Shock: Mechanical durability : 300 m/s² (approx. 30 G), Malfunction durability : 100 m/s² (approx. 10 G)
- Life expectancy: Mechanical : 10,000,000 operations Min, Electrical : 100,000 operations Min. (250 V a.c 3 A)
- Weight: GF4 - P : 184 gms, GF4 - T : 168 gms (with adaptor), GF4 - P41S : 100 gms
- Power supply: 100 - 240 V a.c 50 - 60 Hz
- Power consumption: GF4 - T : 4.8 V A, GF4 - P : 6.2 V A (240 V a.c 60 Hz)
- Reset / Inhibit: Reset by power OFF : Min. power OFF time : 0.5 s, External reset or inhibit : Min. reset input signal width : 0.02 s
- Control output: SPDT : 250 V a.c 3 A cosØ = 1(resistive load), Open collector: 30 V d.c Max. 100 mA Max.
- Ambient temperature Operating: -10 °C to 55 °C
- Humidity: 35 to 85 % R.H.